STRENGTH OF ENDURANCE. PROVIDE PROTECTION FOR RIGOROUS PROCEDURES

The Chemax HRpro® is specially designed to provide superior barrier protection against viruses, bacteria and high risk chemical hazards. This glove is tested for handling of 14 types of chemotherapy drugs, including Thiotepa, and the result show no permeation up to 240 minutes. This glove is made from 100% synthetic material - Nitrile Butadiene Rubber, unlike natural rubber latex, this glove will not induce any Type I latex allergy.

Chemax HRpro® is designed with extra length (25% longer than standard length) to provide better coverage. This glove comes with powder-free finishing that is suitable for use in environment which is sensitive to powder contamination.

Features & Benefits

  • High Level Protection with extra thickness (5.5mil) and extended cuff length (12")
  • NFPA 1999-2013 Certified (USA National Fire Protection Association) for Emergency Medical Service
  • Safe for use with 14 types of chemotherapy drugs
  • European PPE Category III, Complex Design
  • Not made with natural rubber latex

Recommended Application


Resistance of Gloves to Permeation by Chemicals and Chemotherapy Drugs

Resistance to Permeation by Chemicals
(EN 374:2003 Part 3)
Level
5% Ethidium Bromide 6
37% Formaldehyde 6
50% Glutaraldehyde 6
1.5% Methanol in Water 6
0.1% Phenol 6
40% Sodium Hydroxide 6

with measured breakthrough time of minimum 480 minutes for level 6


Chemotherapy Drugs Permeation Test
(ASTM D6978-05 (2013))
 
Cytarabine

Cisplatin
*Cyclophosphamide (Cytoxan)
*Doxorubicin HCI
Dacarbazine (DTIC)
*Etoposide
*Fluorouracil

Ifosfamide
Methotrexate
Mitomycin C
Mitoxantrone
*Paclitaxel (Taxol)
Vincristine Sulfate
*Thiotepa
No Breakthrough after 240 minutes
*Carmustine 15 minutes

* denotes mandatory chemotherapy drugs


Product Specifications & Typical Performance (ASTM D6319 & EN455)

  Specifications Typical
Thickness (mm)
Cuff Min. 0.08 0.10 - 0.12
Palm Min. 0.11 0.13 - 0.15
Finger Min. 0.18 0.20 - 0.26
Dimension (mm)
Length Min. 285 290 - 295
Physical Properties - Unaged
Tensile Strength (MPa) Min. 14 26 - 32
Elongation (%) Min. 500 560 - 630
Force at Break (N) Min. 6.0 16.0 - 19.0
Physical Properties - Aged
Tensile Strength (MPa) Min. 14 27 - 33
Elongation (%) Min. 400 550 - 590
Force at Break (N) Min. 6.0 16.0 - 19.0

typical product performance not to be taken as actual product specification


Color Codes


Product Testament

Comply to International Standard (ASTM D6319 & EN455) FDA 510(k) Pre-market Notification

Biological Evaluation
Primary Skin Irritation Test
Dermal Sensitization Assay
Cytotoxicity Test

Additional Test
Viral Penetration (ASTM F1671)
Chemotherapy Drugs (ASTM D6978)
Chemical Residue
NFPA 1999

Food Handling
US FDA 21 CFR 177.2600
(EU) No. 10/2011 (EN 1186)

MDD Compliance
MDD 93/42/EEC

PPE Compliance
PPE 89/686/EEC, CAT III


Packaging Information


Product Attributes

Powder-Free Chlorinated  |  Fingertips Textured  |  Ambidextrous Extended Cuff  |  Beaded  |  AQL 1.5